Delta-Wye resistance equations
The terminal letters define how each resistance is assigned.
RA = RAB × RCA / (RAB + RBC + RCA)RB = RAB × RBC / (RAB + RBC + RCA)RC = RBC × RCA / (RAB + RBC + RCA)RAB = (RA×RB + RB×RC + RC×RA) / RCRBC = (RA×RB + RB×RC + RC×RA) / RARCA = (RA×RB + RB×RC + RC×RA) / RBwhere:
- RAB
- Delta resistance between A and B[Ω]
- RBC
- Delta resistance between B and C[Ω]
- RCA
- Delta resistance between C and A[Ω]
- RA
- Wye resistance connected to A[Ω]
- RB
- Wye resistance connected to B[Ω]
- RC
- Wye resistance connected to C[Ω]
This page limits the calculation to real resistance.
Delta and Wye terminal mapping
The Delta network has three sides RAB, RBC, and RCA. The equivalent Wye network has three branches RA, RB, and RC connected to terminals A, B, and C.
Balanced conversion example
A balanced Delta network with 30 Ω on every side converts to a Wye network with 10 Ω on every branch. The reverse conversion returns each side to 30 Ω.
30 Ω Δ → 10 Ω Y
10 Ω Y → 30 Ω Δ
Method & Sources
Method
Formula used
RA = RAB × RCA / (RAB + RBC + RCA)RB = RAB × RBC / (RAB + RBC + RCA)RC = RBC × RCA / (RAB + RBC + RCA)RAB = (RA×RB + RB×RC + RC×RA) / RCRBC = (RA×RB + RB×RC + RC×RA) / RARCA = (RA×RB + RB×RC + RC×RA) / RB
Input basis
The terminal letters define how each resistance is assigned.
- Conversion direction
- Network balance
- Balanced Delta resistor [Ω]
- Delta resistor RAB [Ω]
- Delta resistor RBC [Ω]
- Delta resistor RCA [Ω]
- Balanced Wye resistor [Ω]
- Wye resistor RA [Ω]
- Wye resistor RB [Ω]
- Wye resistor RC [Ω]
- RAB — Delta resistance between A and B [Ω]
- RBC — Delta resistance between B and C [Ω]
- RCA — Delta resistance between C and A [Ω]
- RA — Wye resistance connected to A [Ω]
- RB — Wye resistance connected to B [Ω]
- RC — Wye resistance connected to C [Ω]
Units
Ω
Display and rounding
No separate display or rounding rule is stated on this page.
Scope and limits
- All three resistors are positive real resistances.
- The three terminals are A, B, and C.
- Delta sides are RAB, RBC, and RCA; Wye branches are RA, RB, and RC.
- This calculator supports resistance only, not complex inductive or capacitive impedance.
- A mathematically equivalent network can have different component power, voltage stress, and physical arrangement.
- This page limits the calculation to real resistance.
Sources
- Estimation basis: published page formula, assumptions, and warningsEstimation basisNo separate public standard is cited; the published equation and stated input scope form a planning or screening basis.
Unbalanced conversion example
For RAB = 30 Ω, RBC = 60 Ω, and RCA = 90 Ω, the sum is 180 Ω. RA uses RAB and RCA, RB uses RAB and RBC, and RC uses RBC and RCA.
| Wye branch | Calculation | Result |
|---|---|---|
| RA | 30 × 90 / 180 | 15 Ω |
| RB | 30 × 60 / 180 | 10 Ω |
| RC | 60 × 90 / 180 | 30 Ω |
Reverse Wye-to-Delta conversion
Multiply each pair of Wye branches, add all three products, then divide by the branch opposite the required Delta side. The tool makes this mapping automatically.
Resistance-only scope
The equations are valid for real resistance. Inductors and capacitors require complex impedances with phase angle, and component voltage and power can differ even when the external network is equivalent.
Assumptions
- All three resistors are positive real resistances.
- The three terminals are A, B, and C.
- Delta sides are RAB, RBC, and RCA; Wye branches are RA, RB, and RC.
Important Warnings
- This calculator supports resistance only, not complex inductive or capacitive impedance.
- A mathematically equivalent network can have different component power, voltage stress, and physical arrangement.