Select language

Choose the language for the tools.

Electrical Fundamentals & Circuit Analysis

Delta-Wye Conversion Calculator

Convert balanced or unbalanced Delta and Wye resistor networks with explicit RAB, RBC, RCA, RA, RB, and RC terminal mapping.

Delta-Wye resistance equations

The terminal letters define how each resistance is assigned.

RA = RAB × RCA / (RAB + RBC + RCA)
RB = RAB × RBC / (RAB + RBC + RCA)
RC = RBC × RCA / (RAB + RBC + RCA)
RAB = (RA×RB + RB×RC + RC×RA) / RC
RBC = (RA×RB + RB×RC + RC×RA) / RA
RCA = (RA×RB + RB×RC + RC×RA) / RB

where:

RAB
Delta resistance between A and B[Ω]
RBC
Delta resistance between B and C[Ω]
RCA
Delta resistance between C and A[Ω]
RA
Wye resistance connected to A[Ω]
RB
Wye resistance connected to B[Ω]
RC
Wye resistance connected to C[Ω]

This page limits the calculation to real resistance.

Delta and Wye terminal mapping

The Delta network has three sides RAB, RBC, and RCA. The equivalent Wye network has three branches RA, RB, and RC connected to terminals A, B, and C.

Balanced conversion example

A balanced Delta network with 30 Ω on every side converts to a Wye network with 10 Ω on every branch. The reverse conversion returns each side to 30 Ω.

30 Ω Δ → 10 Ω Y

10 Ω Y → 30 Ω Δ

Method & Sources

Method

Formula used

  • RA = RAB × RCA / (RAB + RBC + RCA)
  • RB = RAB × RBC / (RAB + RBC + RCA)
  • RC = RBC × RCA / (RAB + RBC + RCA)
  • RAB = (RA×RB + RB×RC + RC×RA) / RC
  • RBC = (RA×RB + RB×RC + RC×RA) / RA
  • RCA = (RA×RB + RB×RC + RC×RA) / RB

Input basis

The terminal letters define how each resistance is assigned.

  • Conversion direction
  • Network balance
  • Balanced Delta resistor [Ω]
  • Delta resistor RAB [Ω]
  • Delta resistor RBC [Ω]
  • Delta resistor RCA [Ω]
  • Balanced Wye resistor [Ω]
  • Wye resistor RA [Ω]
  • Wye resistor RB [Ω]
  • Wye resistor RC [Ω]
  • RAB — Delta resistance between A and B [Ω]
  • RBC — Delta resistance between B and C [Ω]
  • RCA — Delta resistance between C and A [Ω]
  • RA — Wye resistance connected to A [Ω]
  • RB — Wye resistance connected to B [Ω]
  • RC — Wye resistance connected to C [Ω]

Units

Ω

Display and rounding

No separate display or rounding rule is stated on this page.

Scope and limits

  • All three resistors are positive real resistances.
  • The three terminals are A, B, and C.
  • Delta sides are RAB, RBC, and RCA; Wye branches are RA, RB, and RC.
  • This calculator supports resistance only, not complex inductive or capacitive impedance.
  • A mathematically equivalent network can have different component power, voltage stress, and physical arrangement.
  • This page limits the calculation to real resistance.

Sources

  • Estimation basis: published page formula, assumptions, and warningsEstimation basisNo separate public standard is cited; the published equation and stated input scope form a planning or screening basis.

Unbalanced conversion example

For RAB = 30 Ω, RBC = 60 Ω, and RCA = 90 Ω, the sum is 180 Ω. RA uses RAB and RCA, RB uses RAB and RBC, and RC uses RBC and RCA.

Wye branchCalculationResult
RA30 × 90 / 18015 Ω
RB30 × 60 / 18010 Ω
RC60 × 90 / 18030 Ω

Reverse Wye-to-Delta conversion

Multiply each pair of Wye branches, add all three products, then divide by the branch opposite the required Delta side. The tool makes this mapping automatically.

Resistance-only scope

The equations are valid for real resistance. Inductors and capacitors require complex impedances with phase angle, and component voltage and power can differ even when the external network is equivalent.

Assumptions

  • All three resistors are positive real resistances.
  • The three terminals are A, B, and C.
  • Delta sides are RAB, RBC, and RCA; Wye branches are RA, RB, and RC.

Important Warnings

  • This calculator supports resistance only, not complex inductive or capacitive impedance.
  • A mathematically equivalent network can have different component power, voltage stress, and physical arrangement.

FAQ

What is the Wye equivalent of a balanced 30 Ω Delta?

Each Wye branch is 10 Ω. For equal resistances, the Wye value is one third of the Delta value.

What does 30 / 60 / 90 Ω in Delta convert to?

With RAB = 30 Ω, RBC = 60 Ω, and RCA = 90 Ω, the Wye result is RA = 15 Ω, RB = 10 Ω, and RC = 30 Ω.

Why does terminal mapping matter?

The same three numerical values can produce a different answer if they are assigned to different physical terminals.

Can I convert inductors or capacitors?

Not on this page. Those components require complex impedances with magnitude and phase, especially at a specified frequency.

Does an equivalent network use the same resistor wattages?

No. The external terminal behavior is equivalent, but internal voltage, current, and dissipation can differ.