Motor FLA Calculator: Full Load Amps by HP & Voltage
Calculate motor full-load amps from power or look up NEC Table 430.250 three-phase and Table 430.248 single-phase values by HP and voltage.
Tools for motor current, starter and contactor selection, starting voltage drop, voltage unbalance, and VFD sizing.
12 calculatorsCalculate motor full-load amps from power or look up NEC Table 430.250 three-phase and Table 430.248 single-phase values by HP and voltage.
Estimate motor current, starting current, contactor duty, overload-relay range, and preliminary short-circuit protection for a motor starter.
Calculate three-phase voltage unbalance, voltage-window thresholds, and select a starting VIOX FCP18 monitoring-relay function.
Estimate motor locked-rotor amps from a nameplate NEC Code letter, or apply an editable starting-current multiplier to motor full-load amps.
Calculate induction-motor synchronous speed, slip, rotor speed and rotor frequency from poles, supply frequency and measured speed or known slip.
Correct a measured insulation-resistance value to a reference temperature using a selectable doubling-temperature or entered correction coefficient.
Calculate motor shaft torque, output power, input power, angular speed, and lb-ft from kW or hp, rotational speed, and efficiency.
Estimate an MCC or motor-control-panel feeder ampacity from the largest motor, remaining motors, non-motor load, demand, and spare capacity.
Estimate a contactor current class from load type, power, voltage, utilization category, and operating frequency.
Estimate bus voltage dip during motor starting from motor current, starting method, transformer impedance, and feeder impedance.
Estimate the minimum VFD output-current class and screen input protection, bypass contactor, filtering, braking, and panel heat requirements.
Calculate SSR load current, minimum nameplate-current screen, conduction loss, heatsink thermal resistance, junction temperature, surge margin, and semiconductor-fuse I²t checks.
Motor circuits must carry normal load, tolerate starting current, provide overload and short-circuit protection, and switch the load at the required duty. Motor current is only the first step.
Contactor utilization category, starter method, acceleration time, starts per hour, voltage quality, service factor, and VFD derating can govern the final equipment selection.
Full-load current determines continuous current paths, while locked-rotor or controlled starting current affects voltage dip, magnetic trip compatibility, contactor making duty, and source capacity.
VFD and soft-starter applications require manufacturer data for output current, overload class, carrier frequency, ambient temperature, altitude, cable length, EMC, harmonics, and motor compatibility.
Estimate current, input power, efficiency, torque, and phase behavior.
Compare DOL, star-delta, soft starter, VFD, contactor, and overload requirements.
Screen feeder load, starting voltage drop, voltage unbalance, heat, and protection.
It reflects the actual motor design and rating basis. Formula current is useful when nameplate data is unavailable, but efficiency and power factor assumptions introduce uncertainty.
It reduces line-side starting impact but introduces drive current, overload, harmonic, thermal, EMC, and protection requirements.
No. AC-1, AC-3, AC-4 and other utilization categories have different making, breaking, and endurance duties.