Select language

Choose the language for the tools.

Electrical Fundamentals & Circuit Analysis

Amps to HP Calculator

Convert amps to HP with the correct phase, power-factor, efficiency, time, or voltage basis where the selected conversion requires it.

amps to HP equation

This page isolates the amps to HP relationship so the phase, power-factor, efficiency, or time basis is visible.

Conversion relation
HP = kφ × V × I × PF × η / 745.699872

where:

HP
Mechanical output power[HP]
I
Current[A]
V
Voltage[V]
PF
Power factor
η
Motor efficiency as a decimal
kφ
Phase factor: 1 for DC or single-phase and √3 for balanced three-phase line-to-line voltage

Use consistent units and check whether the input power is electrical input or shaft output.

How to convert amps to HP

Convert amps to HP with the correct phase, power-factor, efficiency, time, or voltage basis where the selected conversion requires it.

  1. Identify the quantities you already know.
  2. Select the applicable phase, power factor, efficiency, or time basis.
  3. Enter nominal values and compare the result with the equipment nameplate.

Worked example

amps to HP: 14 A, 460 V, three-phase AC, 0.88, 92 % gives 12.1 HP.

amps → HP = 12.1 HP

Method & Sources

Method

Formula used

  • HP = kφ × V × I × PF × η / 745.699872

Input basis

This page isolates the amps to HP relationship so the phase, power-factor, efficiency, or time basis is visible.

  • Current [A]
  • Voltage [V]
  • System
  • Power factor
  • Efficiency [%]
  • HP — Mechanical output power [HP]
  • I — Current [A]
  • V — Voltage [V]
  • PF — Power factor
  • η — Motor efficiency as a decimal
  • kφ — Phase factor: 1 for DC or single-phase and √3 for balanced three-phase line-to-line voltage

Units

A · V · % · HP

Display and rounding

No separate display or rounding rule is stated on this page.

Scope and limits

  • Nominal values are used for the entered voltage, phase, power factor, efficiency, or time.
  • Balanced phases and nominal voltage are assumed; verify the actual connection and nameplate values for final engineering use.
  • This is a conversion aid, not a complete equipment selection or protection study.
  • Use consistent units and check whether the input power is electrical input or shaft output.

Sources

Common amps to HP values

The table changes only the first input while retaining the page's documented example assumptions.

Input ampsResult HP
5 amps4.325 HP
10.0 amps8.65 HP
20.0 amps17.3 HP

Assumptions and limits

Balanced phases and nominal voltage are assumed; verify the actual connection and nameplate values for final engineering use.

Formulas and sources

The equations use the SI relationships for electrical power, energy, charge, and the defined mechanical horsepower value. Verify local code, equipment data, and project assumptions before engineering use.

Assumptions

  • Nominal values are used for the entered voltage, phase, power factor, efficiency, or time.
  • Balanced phases and nominal voltage are assumed; verify the actual connection and nameplate values for final engineering use.

Important Warnings

  • This is a conversion aid, not a complete equipment selection or protection study.

FAQ

What formula converts amps to HP?

HP = kφ × V × I × PF × η / 745.699872

Does amps to HP require a power factor?

Yes for AC power calculations. Use the load power factor; enter 1 only for DC or a purely resistive load.

How does phase affect amps to HP?

Three-phase AC uses a √3 factor for line-to-line voltage; single-phase and DC use 1.

Can this amps to HP calculator replace equipment data?

No. Treat the output as a conversion or screening value and verify the actual nameplate, connection, and applicable standard.

Why can HP differ from another calculator?

Different phase conventions, assumed power factor, efficiency, rounding, or whether power is input or output can change the result.